DESIGNING SOLUTIONS FOR NOW THAT ARE READY TO SHAPE THE FUTURE. THIS IS NEXXIS.
HomeKnowledge CentreLatest News

Why use EasyLaser’s Multipoint Program?

So you’re ready to do an alignment and you’re wondering whether to use three measurement points or multiple?  Maybe you’ve repeated the final measurements over and over again, just to be sure on the results.  This is an example where the multipoint function would be a better solution.

multipoint_3points_1

Three measuring points will represent the center of rotation for the shaft

With the basic laser shaft alignment, three readings are used to calculate the result. That means that these three points must perfectly represent the center and axis of the rotation. In most cases this is sufficient, and the possible error negligible. However, in some machines like high speed compressors and turbines, where the tolerances are very small and the measurements must repeat extremely well, a different method will come in handy; Multipoint measurement.

FACTORS INFLUENCING THE RESULT

There are many reasons for minor variations in the measuring results. For example vibrations from neighbouring machines, temperature variation and bearing clearances are some. The direction of measurement has also influence on the result. Piston engines and reciprocating compressors create a slightly oval movement on the outgoing shaft when rotated, and machines resting on damper feet may have unexpected movement during alignment.

multipoint_screen_4pts

Software guides to best measurement positions

Since the Multipoint program allow multiple readings to be recorded, we will be able to make, what we very simplified can call an “average”. But it’s not only the number of points that counts. The angular position has a great influence on the result. The program guides the user with red and green color to select the positions that will improve the accuracy most.

multipoint_average_1

Multipoint will use the ”average” to calculate the center of rotation

LIMITED ROTATION

In some case, only a smaller arc can be used for the alignment due to the machine design. Pipework, brakes etc. may limit the rotation. In that case, the measurement becomes more sensitive to fluctuation in the readings. Taking additional measurements will effectively reduce the influence from vibrations etc. Combined with a proper filter level, measurement can be done in almost any condition. The minimum rotation in Multipoint is 40 degrees, same as the other programs, but with multiple readings within that range, the result quality will be even better.

multipoint_nonrotating_1

The surface quality will affect the accuracy when measuring on non rotating shafts

NON ROTATING SHAFTS

Another application for Multipoint is non rotating shafts. When using sliding brackets, the measurement depend on the surface quality rather than the true rotational axis. That means, every distortion on the surface will reduce the result accuracy. Additional readings spread as much as possible, if accessible all around the shaft, will give a reliable result even in difficult situations.

TURBINES

When measuring on a turbine, Multipoint is a must. A 360 degree rotation, if possible, with at least 6-8 measurement points will give a high accuracy. In environment with excessive vibrations, the filter will stabilize the readings. Since the system measure the rotation by itself, the shaft can be rotated to any position and any number of turns before taking next reading. That simplifies a lot in case the shaft have to be rotated with a sling as the shaft may stop rotation anywhere. Make sure that any drag from the sling is removed before taking each reading. The quality of the result can of course also be checked with the built-in analysis feature.

If you haven’t started the Multipoint program yet, I suggest that you give it a try!

*This article was originally created by Leif Törngren / Technical Supervisor at EasyLaser
Join our mailing list // Discover a world of forward-looking solutions designed to shape the future. Ready?