Panther Phased Array Systems
GENERAL
L x W x H:
300mm x 220mm x 155mm
Weight:
6kg
Operating temperature range:
from -10°C to 50°C | 14°F to 120°F
IP54
Storage temperature range:
-10°C to 60°C | 14°F to 140°F
Power supply:
240V50Hz – 110V/60Hz
PHASED-ARRAY
Linear scanning, sectorial scanning, parallel shooting, ultrafast mixed modes
Linear, Matrix, DLA and DMA, Annular and Daisy probes
Maximum active aperture:
2048 channels (with 16 Panther units)
Unlimited probe number | No group limitation | Up to 13100 focal laws
Delay-law computation for standard and parametric components (plates, pipes, TKY junctions, nozzle, elbows, turbine blades…) as well as 2D and 3D CAD
Focusing mode:
true depth, sound path, projection
REAL-TIME TFM, FMC, PWI
Reconstruction channels:
up to 128
Max number of pixels for the reconstructed image:
more than 1 Million
Max refresh rate:
up to 500fps (depends on the pixel numbers)
Multiple Sound paths:
direct (L or S), indirect and converted modes, Modes superposition
PULSERS
128 phased-array channels*:
Bipolar square pulse, width: 30ns to 2000ns
Voltage amplitude: max 180V with 1V step
Max. PRF: up to 40kHz
RECEIVERS
128 phased-array channels*:
Input impedance: 50 Ω
Gain: up to 120dB (0.1dB step)
Frequency range: 0.4 to 20MHz
Cross-talk between two channels < 50 dB
Max. input signal: 1.8Vpp
Ultralow noise amplifier
DIGITIZER
Digitizing and real-time summation on 128 channels
Resolution:
14bit
Dynamic:
16bit
IIR filters
Max. sampling frequency:
125 MHz
Rectified, RF, envelope
Digitizing depth:
up to 16k points
Max delay:
1.6 ms
Max A-scan range:
65k points
ACQUISITION
A-Scan/Peak data recording
800% amplitude range
High speed FMC recording (320 MB/s)
Inspection data file size:
hard drive limitation
Acquisition trigger on time, event, encoder
Data transfer through USB3
WIZARDS
CAD overlay and 3D view
Amplitude balancing
Real-time phased array calculator
Probe design | Weld geometry design
Wedge calibration (angle, height)
Amplitude calibration (TCG, DAC)
Part geometry with parametric shapes (plates, cylinders, Butt Welds, T K & Y welds, elbow, blade, nozzles,…), 2D and 3D CAD
ANALYSIS
Powerful CIVA Analysis© and EnlightTM software with analysis and reporting tools
Amplitude range:
up to 800%
A-Scan, B-Scan, C-Scan, D-Scan, Echodynamic, Top – Side – Front views
CAD part geometry:
plate, cylinder, T or Y section, nozzle