Cygnus 6+ PRO
MEASURING MODES
-
Multiple-Echo: Ignores coatings up to 20 mm (0.8″)
-
Echo-Echo: Ignores coatings up to 1 mm (0.04″)
-
Single-Echo: For corroded or uncoated materials
MATERIALS
-
Velocity range: 1,000 – 9,000 m/s (0.0390 – 0.3543 in/μs)
ACCURACY
-
±0.05 mm (±0.002″) – in Multiple-Echo mode
-
±0.1 mm (±0.004″) or 0.1% of reading – in Echo-Echo and Single-Echo modes
RESOLUTION
-
Multiple-Echo: 0.1 mm or 0.05 mm
-
Echo-Echo & Single-Echo: 0.1 mm or 0.01 mm
PROBES
-
Compatible with single crystal, twin crystal, and high temperature probes
MEASUREMENT RANGE (STEEL)
-
0.8 – 250 mm (0.031 – 10 in), depending on probe and setup
TEMPERATURE COMPENSATION
-
Supports Cygnus High Temperature Probe for in-service inspection of hot assets
CONNECTOR
-
2 x Lemo 00
POWER
-
3 x AA (R6) batteries
-
Battery Life: Approx. 10 hours
ELECTRONICS
-
Dual channel pulser
DISPLAYS
-
Front LCD: 2.4” QVGA (47 x 37 mm)
-
End-mounted LCD: 25.58 x 6.38 mm (grayscale option for sunlight readability)
SIZE & WEIGHT
-
Size: 84 x 130 x 35 mm
-
Weight: 300 g (with batteries)
OPERATING TEMP.
-
-10°C to +50°C (14°F to 122°F)
DATA LOGGING
-
5,000 measurements and A-scans per record
-
Max number of records: 100 (soft limit)
SOFTWARE
-
CygLink for remote logging, A-scan viewing, PDF report creation, and data/statistical analysis
-
Bluetooth enabled for data transfer
ALERTS & FEATURES
-
Freeze function
-
Min/Max limit alarms with visual and vibrate alerts
-
Manual and automatic gain control
-
One- and two-point calibration
ENVIRONMENTAL RATING
-
IP67 sealed housing
-
Certified safe for Class I, Division 2, Group D locations (NFPA 70, Article 500)
-
MIL STD 810G tested:
-
Method 501.6 (High temp +55°C)
-
Method 502.6 (Low temp -20°C)
-
Method 507.6 (Humidity 95%)
-
Method 512.6 (Immersion 1 m for 30 mins)
-
Method 514.7 (Vibration)
-
Method 516.7 (Shock 20g, Transit drop 1.22 m)
-
COMPLIANCE & STANDARDS
-
Designed for EN 15317
-